Select model
  • Model Part no
    Request
  • Fine filter
    404901
    Request
  • Pre-filter, DC 380/DC AirCube
    4080
    Request
  • Fine filter
    408801
    Request
  • Fine filter
    408803
    Request
  • HEPA filter (fitted in the fine filter)
    4133
    Request
  • HEPA filter
    42024
    Request
  • Fine filter
    42025
    Request
  • HEPA filter, DC AirCube
    42136
    Request
  • Fine filter, grounded
    42398
    Request
  • Fine filter, PTFE
    42465
    Request
  • Pre-Filter, Aircube 200
    42619
    Request
  • HEPA filter, DC 3500 (installed on exhaust)
    4366
    Request
  • HEPA filter, DC 5500 5 kW, 9.2 kW S (installed under top cover)
    4422
    Request
  • Pre-filter, DC 1500
    4669
    Request
  • HEPA filter K
    4821
    Request
  • HEPA filter, DC 3500 TR
    4889
    Request
  • Fine filter x 24
    42025ST
    Request
  • Fine filter x 24
    42026ST
    Request
  • Fine filter
    42026
    Request

Cellulose Fine Filter
Good quality standard filter with high filtration efficiency. Epoxy treated for resistance to humidity and other elements.

Polyester Fine Filter
High quality filter material with exceptional resistance to most elements. Particularly suitable to high humidity applications such as machine and tool shops where cutting and cooling fluids are used. Filter can be washed.

HEPA Filter
The HEPA filter is made of fibreglass material with a support layer of cellulose. Filtration efficiency is 99.995% EN 60335. Note: When changing filters the gasket of the filter holder has to be checked and cleaned. Leakage is not permitted in Asbestos applications.

Filters for earlier models
DC 2500i, DC 2500, DC 2500 Twin
Part No Description Construction Material Area [m2 /ft2] Classification Max temp
4889 Fine filter Pleated Polyester 1.4 /15 IEC EN 60335-2-69 Part 1 266°F /130°C
404901 Fine filter Pleated around
support cylinder
Cellulose 1.5 /16.2 IEC EN 60335-2-69 Part 1 158°F /70°C
4821 HEPA filter K Pleated Cellulose, fibreglass 1.5 /16.2 HEPA H13 EN 1822-1 158°F /70°C
4133 HEPA filter
(fitted in the fine filter)
Pleated around
support cylinder
Cellulose, fibreglass 0.5 /5.4 HEPA H13 EN 1822-1 176°F/80°C
 

DC 2700c, DC 2700i, DC 2800c, DC 2800c Rental
Machines from serial number 2527595 can be equipped with the new, separate HEPA filter (Part No 42027). Older models should be equipped with a HEPA combi-filter.

Part No Description Construction Material Area [m2 /ft2] Classification Max temp
4889 Fine filter Pleated Polyester 1.4 /15 IEC EN 60335-2-69 Part 1 266°F /130°C
404901 Fine filter Pleated around
support cylinder
Cellulose 1.5 /16.2 IEC EN 60335-2-69 Part 1 158°F /70°C
4821 HEPA filter K Pleated Cellulose, fibreglass 1.5 /16.2 HEPA H13 EN 1822-1 158°F /70°C
4133 HEPA filter
(fitted in the fine filter)
Pleated around
support cylinder
Cellulose, fibreglass 0.5 /5.4 HEPA H13 EN 1822-1 176°F/80°C
 

DC 3700c

Part No Description Construction Material Area [m2 /ft2] Classification Max temp
42026 Fine filter Pleated around
support cylinder
Cellulose 1.8 /19.4 IEC EN 60335-2-69 Part 1 176°F/80°C
42025 Fine filter Pleated around
support cylinder
Polyester 1.8 /19.4 IEC EN 60335-2-69 Part 1 176°F/80°C
 

DC 3500, DC 3500TR, DC 3500 Stationary, DC 5500, DC 5500i

Part No Description Construction Material Area [m2 /ft2] Classification Max temp
408801 Fine filter Pleated Polyester 1.6 /17 IEC EN 60335-2-69 Part 1 176°F/80°C
408803 Fine filter Pleated Cellulose 1.6 /17 IEC EN 60335-2-69 Part 1 176°F/80°C
4821 HEPA filter, DC 3500 TR Pleated Cellulose, Fibreglass 1.5 /16.2 HEPA H13 EN 1822-1 158°F /70°C
4366 HEPA filter, DC 3500 (installed
on exhaust)
Pleated around
support cylinder
Cellulose, Fibreglass 1.2 /12.9 HEPA H13 EN 1822-1 176°F/80°C
4422 HEPA filter, DC 5500 5 kW, 9.2
kW S (installed under top cover)
Pleated around
support cylinder
Cellulose, Fibreglass 2.5 /26.9 HEPA H13 EN 1822-1 176°F/80°C
4017 HEPA filter, DC 5500 9.2 kW P
(installed on exhaust)
Pleated around
support cylinder
Cellulose, Fibreglass 2.8 /30 HEPA H13 EN 1822-1 176°F/80°C
 

DC 3500i, DC 5700c, DC 5800 a/c 5 kW, DC 5800 a/c PTFE

Part No Description Construction Material Area [m2 /ft2] Classification Max temp
4917 Combi-filter DC 3500i (Fine filter
+ HEPA H13 filter)
Pleated Cellulose, fibreglass 1.5 /16.2 HEPA H13 EN 1822-1 176°F/80°C
4422 HEPA filter, DC 5700 5 kW, 9.2
kW S (installed under top cover)
Pleated around
support cylinder
Cellulose, fibreglass 2.5 /26.9 HEPA H13 EN 1822-1 176°F/80°C
4017 HEPA filter, DC 5700 9.2 kW P
(installed on exhaust)
Pleated around
support cylinder
Cellulose, fibreglass 2.8 /30 HEPA H13 EN 1822-1 176°F/80°C
 

Air Cleaners DC 380, DC 1500, DC AirCube

Part No Description Construction Material Area [m2 /ft2] Classification Max temp
4080 Pre-filter, DC 380/DC AirCube Carpet Polyester 0.1 /1 IEC EN 60335-2-69 Part 1 212°F/100°C
4669 Pre-filter, DC 1500 Carpet Polyester 0.3 /3.2 IEC EN 60335-2-69 Part 1 212°F/100°C
42136 HEPA filter, DC AirCube Pleated HEPA
filter box
Glasfaser 5.2 /55.9 EN 1822-1, HEPA H13 212°F/100°C
 

DC 3800a/c, DC 3800c Turbo, DC 3800 Turbo EX, DC 3800c Twin, DC 3800 TR S, DC 3800i, DC 3800 Stationary

Part No Description Construction Material Area [m2 /ft2] Classification Max temp
42026 Fine filter Pleated around
support cylinder
Cellulose 1.8 /19.4 IEC EN 60335-2-69 Part 1 176°F/80°C
42025 Fine filter Pleated around
support cylinder
Polyester 1.8 /19.4 IEC EN 60335-2-69 Part 1 176°F/80°C
42465 Fine filter, PTFE Pleated around
support cylinder
Polyester, PTFE 1.8 /19.4 IEC EN 60335-2-69 Part 1 176°F/80°C
42024 HEPA filter Pleated around
support cylinder
Cellulose, Fibreglass 1.5 /16.2 HEPA H13 EN 1822-1 176°F/80°C
42398 Fine filter, grounded Pleated around
support cylinder
Polyester 1.8 /19.4 IEC EN 60335-2-69 Part 1 176°F/80°C
4202501 Fine filter antistatic Pleated around
support cylinder
Polyester, antistatic 1.5 /16.2 IEC EN 60335-2-69 Part 1 176°F/80°C

 

For more detailed information, please read our

 

Consumables, Filters

Filters Older Models

Filters Older Models

 

Select model
  • Model Part no
    Request
  • Fine filter
    404901
    Request
  • Pre-filter, DC 380/DC AirCube
    4080
    Request
  • Fine filter
    408801
    Request
  • Fine filter
    408803
    Request
  • HEPA filter (fitted in the fine filter)
    4133
    Request
  • HEPA filter
    42024
    Request
  • Fine filter
    42025
    Request
  • HEPA filter, DC AirCube
    42136
    Request
  • Fine filter, grounded
    42398
    Request
  • Fine filter, PTFE
    42465
    Request
  • Pre-Filter, Aircube 200
    42619
    Request
  • HEPA filter, DC 3500 (installed on exhaust)
    4366
    Request
  • HEPA filter, DC 5500 5 kW, 9.2 kW S (installed under top cover)
    4422
    Request
  • Pre-filter, DC 1500
    4669
    Request
  • HEPA filter K
    4821
    Request
  • HEPA filter, DC 3500 TR
    4889
    Request
  • Fine filter x 24
    42025ST
    Request
  • Fine filter x 24
    42026ST
    Request
  • Fine filter
    42026
    Request

Related products

Dustcontrol UK Ltd., 7 Beaufort Court , Roebuck Way Knowlhill, Milton Keynes MK5 8HL