Consumables, Filters

Filters Older Models

Filters Older Models

 

Select model
  • Model Part no
    Request
  • Fine filter 404901
    Request
  • Pre-filter, DC 380/DC AirCube 4080
    Request
  • Fine filter 408801
    Request
  • Fine filter 408803
    Request
  • HEPA filter (fitted in the fine filter) 4133
    Request
  • HEPA filter 42024
    Request
  • Fine filter 42025
    Request
  • HEPA filter, DC AirCube 42136
    Request
  • Fine filter, grounded 42398
    Request
  • Fine filter, PTFE 42465
    Request
  • Pre-Filter, Aircube 200 42619
    Request
  • HEPA filter, DC 3500 (installed on exhaust) 4366
    Request
  • HEPA filter, DC 5500 5 kW, 9.2 kW S (installed under top cover) 4422
    Request
  • Pre-filter, DC 1500 4669
    Request
  • HEPA filter K 4821
    Request
  • HEPA filter, DC 3500 TR 4889
    Request
  • Fine filter x 24 42025ST
    Request
  • Fine filter x 24 42026ST
    Request
  • Fine filter 42026
    Request

Cellulose Fine Filter
Good quality standard filter with high filtration efficiency. Epoxy treated for resistance to humidity and other elements.

Polyester Fine Filter
High quality filter material with exceptional resistance to most elements. Particularly suitable to high humidity applications such as machine and tool shops where cutting and cooling fluids are used. Filter can be washed.

HEPA Filter
The HEPA filter is made of fibreglass material with a support layer of cellulose. Filtration efficiency is 99.995% EN 60335. Note: When changing filters the gasket of the filter holder has to be checked and cleaned. Leakage is not permitted in Asbestos applications.

Filters for earlier models
DC 2500i, DC 2500, DC 2500 Twin
Part NoDescriptionConstructionMaterialArea [m2 /ft2]ClassificationMax temp
4889Fine filterPleatedPolyester1.4 /15IEC EN 60335-2-69 Part 1266°F /130°C
404901Fine filterPleated around
support cylinder
Cellulose1.5 /16.2IEC EN 60335-2-69 Part 1158°F /70°C
4821HEPA filter KPleatedCellulose, fibreglass1.5 /16.2HEPA H13 EN 1822-1158°F /70°C
4133HEPA filter
(fitted in the fine filter)
Pleated around
support cylinder
Cellulose, fibreglass0.5 /5.4HEPA H13 EN 1822-1176°F/80°C
 

DC 2700c, DC 2700i, DC 2800c, DC 2800c Rental
Machines from serial number 2527595 can be equipped with the new, separate HEPA filter (Part No 42027). Older models should be equipped with a HEPA combi-filter.

Part NoDescriptionConstructionMaterialArea [m2 /ft2]ClassificationMax temp
4889Fine filterPleatedPolyester1.4 /15IEC EN 60335-2-69 Part 1266°F /130°C
404901Fine filterPleated around
support cylinder
Cellulose1.5 /16.2IEC EN 60335-2-69 Part 1158°F /70°C
4821HEPA filter KPleatedCellulose, fibreglass1.5 /16.2HEPA H13 EN 1822-1158°F /70°C
4133HEPA filter
(fitted in the fine filter)
Pleated around
support cylinder
Cellulose, fibreglass0.5 /5.4HEPA H13 EN 1822-1176°F/80°C
 

DC 3700c

Part NoDescriptionConstructionMaterialArea [m2 /ft2]ClassificationMax temp
42026Fine filterPleated around
support cylinder
Cellulose1.8 /19.4IEC EN 60335-2-69 Part 1176°F/80°C
42025Fine filterPleated around
support cylinder
Polyester1.8 /19.4IEC EN 60335-2-69 Part 1176°F/80°C
 

DC 3500, DC 3500TR, DC 3500 Stationary, DC 5500, DC 5500i

Part NoDescriptionConstructionMaterialArea [m2 /ft2]ClassificationMax temp
408801Fine filterPleatedPolyester1.6 /17IEC EN 60335-2-69 Part 1176°F/80°C
408803Fine filterPleatedCellulose1.6 /17IEC EN 60335-2-69 Part 1176°F/80°C
4821HEPA filter, DC 3500 TRPleatedCellulose, Fibreglass1.5 /16.2HEPA H13 EN 1822-1158°F /70°C
4366HEPA filter, DC 3500 (installed
on exhaust)
Pleated around
support cylinder
Cellulose, Fibreglass1.2 /12.9HEPA H13 EN 1822-1176°F/80°C
4422HEPA filter, DC 5500 5 kW, 9.2
kW S (installed under top cover)
Pleated around
support cylinder
Cellulose, Fibreglass2.5 /26.9HEPA H13 EN 1822-1176°F/80°C
4017HEPA filter, DC 5500 9.2 kW P
(installed on exhaust)
Pleated around
support cylinder
Cellulose, Fibreglass2.8 /30HEPA H13 EN 1822-1176°F/80°C
 

DC 3500i, DC 5700c, DC 5800 a/c 5 kW, DC 5800 a/c PTFE

Part NoDescriptionConstructionMaterialArea [m2 /ft2]ClassificationMax temp
4917Combi-filter DC 3500i (Fine filter
+ HEPA H13 filter)
PleatedCellulose, fibreglass1.5 /16.2HEPA H13 EN 1822-1176°F/80°C
4422HEPA filter, DC 5700 5 kW, 9.2
kW S (installed under top cover)
Pleated around
support cylinder
Cellulose, fibreglass2.5 /26.9HEPA H13 EN 1822-1176°F/80°C
4017HEPA filter, DC 5700 9.2 kW P
(installed on exhaust)
Pleated around
support cylinder
Cellulose, fibreglass2.8 /30HEPA H13 EN 1822-1176°F/80°C
 

Air Cleaners DC 380, DC 1500, DC AirCube

Part NoDescriptionConstructionMaterialArea [m2 /ft2]ClassificationMax temp
4080Pre-filter, DC 380/DC AirCubeCarpetPolyester0.1 /1IEC EN 60335-2-69 Part 1212°F/100°C
4669Pre-filter, DC 1500CarpetPolyester0.3 /3.2IEC EN 60335-2-69 Part 1212°F/100°C
42136HEPA filter, DC AirCubePleated HEPA
filter box
Glasfaser5.2 /55.9EN 1822-1, HEPA H13212°F/100°C
 

DC 3800a/c, DC 3800c Turbo, DC 3800 Turbo EX, DC 3800c Twin, DC 3800 TR S, DC 3800i, DC 3800 Stationary

Part NoDescriptionConstructionMaterialArea [m2 /ft2]ClassificationMax temp
42026Fine filterPleated around
support cylinder
Cellulose1.8 /19.4IEC EN 60335-2-69 Part 1176°F/80°C
42025Fine filterPleated around
support cylinder
Polyester1.8 /19.4IEC EN 60335-2-69 Part 1176°F/80°C
42465Fine filter, PTFEPleated around
support cylinder
Polyester, PTFE1.8 /19.4IEC EN 60335-2-69 Part 1176°F/80°C
42024HEPA filterPleated around
support cylinder
Cellulose, Fibreglass1.5 /16.2HEPA H13 EN 1822-1176°F/80°C
42398Fine filter, groundedPleated around
support cylinder
Polyester1.8 /19.4IEC EN 60335-2-69 Part 1176°F/80°C
4202501Fine filter antistaticPleated around
support cylinder
Polyester, antistatic1.5 /16.2IEC EN 60335-2-69 Part 1176°F/80°C

 

For more detailed information, please read our

 

Consumables, Filters

Filters Older Models

Filters Older Models

 

Select model
  • Model Part no
    Request
  • Fine filter 404901
    Request
  • Pre-filter, DC 380/DC AirCube 4080
    Request
  • Fine filter 408801
    Request
  • Fine filter 408803
    Request
  • HEPA filter (fitted in the fine filter) 4133
    Request
  • HEPA filter 42024
    Request
  • Fine filter 42025
    Request
  • HEPA filter, DC AirCube 42136
    Request
  • Fine filter, grounded 42398
    Request
  • Fine filter, PTFE 42465
    Request
  • Pre-Filter, Aircube 200 42619
    Request
  • HEPA filter, DC 3500 (installed on exhaust) 4366
    Request
  • HEPA filter, DC 5500 5 kW, 9.2 kW S (installed under top cover) 4422
    Request
  • Pre-filter, DC 1500 4669
    Request
  • HEPA filter K 4821
    Request
  • HEPA filter, DC 3500 TR 4889
    Request
  • Fine filter x 24 42025ST
    Request
  • Fine filter x 24 42026ST
    Request
  • Fine filter 42026
    Request

Related products

Dustcontrol UK Ltd., 7 Beaufort Court , Roebuck Way Knowlhill, Milton Keynes MK5 8HL